IV Therapy
Infusion Equipment and Supplies:
|

$2571.43
|
B Braun Vista
Dimensions: 5.5"W x 9.4"H x 7.8"D
Battery:- 7.2V, 1.2Ah NiCad rechargeable
Battery Operating Time: 3.5 hours at max delivery rate
Rate Range:0.1-800 ml/hr in 0.1 ml increments with Vista™ tubing
Volume to be Infused:0.1-9999.9 ml
Occlusion Pressure: Variable Settings: Low - 8 PSI, High - 17 PSI
KVO Rate: 1 ml/hr or selected rate whichever is lower
Flow Rate Accuracy: ±5%
Mode/Features:
Continuous and Piggyback Modes
Program Mode for variable infusions
Ramp/Taper Mode for TPN infusions
Delay A Mode for postponing start and finish
|
|

$2695.00
|
Graseby 3400
Wide infusion rate range: 0.1-1200 ml/hr
Multiple unit selection: ml/hr, ug/hr, mg/hr, ug/kg/hr, mg/kg/hr, ug/kg/mn, mg/kg/mn
Syringe size flexibility: 5ml, 10ml, 20ml, 30ml, 50/60ml
Simple operation: Menu driven display
Cost effective: No dedicated disposables
AC or battery operated (internal rechargeable battery)
Accurate: +/- 2%
|
|

Refurbished: Please call for pricing.
|
Baxter AS50
Configurable Drug Library
Syringe Plunger Detection
Backlight Display
Adjustable Occlusion Specialty
Selectable Modes of Delivery
Accepts Syringe Sizes from 1-60cc
Battery Voltage Indicator
Adjustable "Near End" Alert
RS232 Communication Port
|
|

Refurbished: Please call for pricing.
|
Baxter Infus O.R.
Modify dose without multiple reprogramming steps.
Adjust settings easily at any time during infusion.
Change dial settings with a single hand for an immediate response.
Save calculation time.
Minimize risk of calculation error.
Change Infusion Parameters/Rates with SMART LABELS
SMART LABELS are magnetically coded/drug specific.
Select from the available SMART Label library.
Ideal for administering drugs requiring multiple dosage adjustments.
SPECIFICATIONS:
Syringes - Monoject® or B-D®; Monoject® or B-D® 20 cc
Accuracy – Infusion: linear rate ±3%. Bolus: linear displacement ±3%.
Battery Life – Typical Use: 150 hours; at low battery and typical use: 4 hours
Flow Rates – 0-600 mL/hr
Flow Profile – Bolus: Continuous; Infusion: Pulsed Intermittently
Occlusion Force – 8 ± 1 lb.
Maximum Occlusion Pressure – 11 psi with 60 cc syringe; 20 psi with 20 cc syringe
Occlusion Detection Time – 120 seconds at 36 mL/hr (inverse related to flow rate)
Volume Stored on Occlusion – 1.1 mL (approx.)
Back Pressure Effect on Accuracy – None to Occlusion Pressure
|
|

Refurbished: Please call for pricing.
|
Smith's Medfusion 3500
FlowSentry™ : enhanced pressure trending for earlier clinical intervention
Extensive delivery mode combinations including ml/hr, body weight, mass, volume over time, custom dilution and intermittent, loading dose, bolus dose, standby, volume limit and KVO rate
Syringe sizes: accepts seven different manufactures syringe types, all manufacture’s syringe administration sets
+/- 2% instrument accuracy: automatic syringe size detection
Ergonomic, easy to use, horizontal design protects entire syringe barrel and allows single-handed loading
MRI indicated: for MRI rooms mounted outside the 150 Gauss line and with shielded magnets of field strength of 1.5 Tesla or less.
Mounts easily to an IV pole, an infant’s isolet or radiant warmer and rotation capabilities
Bio-Med log-on line to set PM dates, view service history, and for access to calibration and diagnostic testing
Internal battery capacity 10 hours at 5.0 ml/hr with 60ml syringe
Wide- ranging flow rates and the capacity to infuse at low flow rates with larger syringes
|
|

Refurbished: Please call for pricing.
|
Baxter AS40
Rate Parameters: 0.001 - 360 ml/hr, syringe-dependent
Syringe Sizes: BD 1, 3, 5, 10, 20, 30, 60 ml. Monoject 1, 3, 6, 12, 20, 35, 60 ml. Terumo 1, 3, 5, 10, 20, 30, 60
Volume limit: Full syringe can be delivered
Battery capacity: 12 hours of operation at 2 ml/hr using 60 ml syringe, following a 16-hour charge
Bottom LCD-Total volume delivered
Accuracy: ± 3 %, not including syringe tolerance
|
|
|